Configure GPI

Configure GPI examples for the ATEM

Example 1 - ATEM: Program Src
Sets source on the given M/E row.
If Hold Down is selected, the source will fall back to the previous source whenever the trigger is released. Toggle will select the source, but on a subsequent trigger, it will fall back to the previous value. If Cycle mode is selected, a trigger will set the next source on Program.

 

Example 2 - ATEM: AUX Output Src
Sets AUX source on the given AUX bus.
If Hold Down is selected, the source will fall back to the previous source whenever the trigger is released. Toggle will select the source, but on a second trigger, it will fall back to the previous value. Hold Groups will fall back to a previous source for a group of triggers using a queue system and finally to the first previous value before any trigger in the group was activated. If Cycle mode is selected, a trigger will set the next source on the AUX bus.

 

Example 3 - ATEM: Upstream Keyer
Turns upstream keyers on and off.
If Toggle mode, the given upstream keyer is turned or/off successively. If On or Off the upstream keyer is set On or Off respectively. Hold Down will turn the keyer on as long as the trigger is held. Auto will fade in the keyer.

 

Example 4 - ATEM: Downstream Keyer
Turns downstream keyers on and off.
If Toggle mode, the given downstream keyer is turned or/off successively. If On or Off the downstream keyer is set On or Off respectively. Hold Down will turn the keyer on as long as the trigger is held. Auto will fade in the keyer.

 

Example 5 - ATEM: Cut
Performs a cut.

 

Example 6 - ATEM: Audio
Sets audio sources to on/off, AFV or solo, including XLR, AES, RCA, Master and Monitor.
If Hold Down is selected, the audio source will be set to the defined parameter (on, AFV or solo) until the trigger is released. In Toggle mode, the given audio source is turned on/off successively. If Cycle mode is selected the audio source will toogle between on, AFV and off.

 
Configure GPO examples for the ATEM

Example 1 - ATEM: Program Src
On when actual Program Src matches selected source.

 

Example 2 - ATEM: AUX Output Src
On when actual AUX bus source matches selected source.

 

Example 3 - ATEM: Upstream Keyer
On if the keyers state corresponds to the selected mode. For most modes except "Off" this means it will be on (but for Off, it will be on in case the keyer is actually off).

 
Defining multiple actions

For GPI it is possible to set multiple actions. You can even add a system wait time to have a pause between actions to be performed.

Example 1 - ATEM: Aux Src + ATEM: Play Macro
Set different sources on AUX 1-6 and begins to loop macro number 8. In this case for AUX 5, the source is set to MV1/1, which means, it's the soure on Multiviewer 1, tile 1.

 

Example 2 - ATEM: Upstream Keyer Key + Upstream Keyer Fill + Upstream Keyer (Auto)
These 3 multiple actions could be used to fade in a lower third on Keyer 1, while setting the keyer key and the keyer fill.

 

Example 3 - ATEM: FTB + System: Wait + ATEM: AUX Src
You can set a system wait time, in order to have pauses between actions performed.